Cooling Tower In HVAC

Strainers - Mr. GoodTowerCooling tower is a peripheral tools that removes heat from the new water that’s pumped from the condenser to the tower. It is done by using the air from the encompassing to reduce the temperature of the water. The air might be natural or compelled by way of fan. The capacity to cool the water is dependent upon the evaporation of the water when air comes in contact with the water.

This relies on the humidity of the surrounding air. Usually the tower ought to be capable to cool the water by about 6°F to 7°F of the air wet bulb temperature. For example, if the wet bulb temperature of the air is 78°F and the recent water coming to the tower from the condenser is 95°F, then the cooled water that leaves the tower will be 85°F, about 7°F decrease than the air wet bulb temperature.

Ideas Of Operation

An example of the applying is using this gear to cool the water-cooled condenser from a chiller system. The hot water from the chiller condenser which could be located within the building is piped to the cooling tower. Pumps are used to circulate the water from the condenser to the tower and back.

The new water is sprayed by means of nozzle onto the thin films supplies (also called fill) which might be manufactured from plastic, wood slats or metallic fins. Their surfaces can be in the shape of honeycomb, corrugated sheet or flat sheet.

Because the water flows by means of these materials, air from the encompassing which may be natural-draft or pressured-draft rushed by way of it and in the process evaporates a few of it. This cools the water which is then collected at the lower sump and through a filter to eliminate leaves and other materials before being circulated again to the condenser.

A drain is used to remove the laborious water minerals from the system. As the quantity of water will cut back due to evaporation and draining, a float valve is used to add the water to the system.

The tower must be located in an space the place the ventilation is nice and never located too close to the constructing. This is vital for the pure-draft tower the place the cooling is finished naturally.

A typical cooling tower.

Pre-caution

Open ...

In temperate international locations, the water can freeze during winter when the temperature drops beneath 32°F or 0°C. Hence, anti-freeze chemical and a heater are essential for proper operation during this time. Pipes should be insulated to forestall the loss of heat. Chemicals are additionally added to prevent the formation of algae, fungus and different micro-organism in the water

Study also confirmed that Legionella micro organism could develop in the cooling tower water. Hence, it is usually important so as to add disinfectants akin to chloride compounds into the water. The extent is maintained commonly and testing of the micro organism is to be carried out in situations where the spread of Legionnaire illness is rampant.

These days, the supplies which can be used to assemble the gear are manufactured from galvanized or stainless steel for easy upkeep. Non-metallic tower tends to degrade over time especially in polluted and harsh setting. Even the elements inside the tower similar to fan blades are additionally being constructed using fiberglass strengthened polyester or FRP. Epoxy can be used to coat them for safety from the extremely violet rays.

Evaporative Condensers

A condenser which is situated inside a cooling tower where it’s cooled is also referred to as an evaporative condenser. In this case, the refrigerant within the condenser is instantly cooled by the water in the tower. The identical process occur in that the water from the tower is pumped and recirculated.

The water is discharged from the nozzle at the highest of the tower and is allowed to drip on the coil of the condenser. This prompted the new refrigerant to cool and a few portion of the water to evaporate.

A fan is used to pressure the air through the coil the place the water is being dripped. A float valve is used to substitute the water that has evaporated on account of them dripping over the recent coil. A drain is used to drain out the concentrated minerals from the water system.

Anti-freeze chemical can also be used to prevent the freezing of the water. Chloride based compound can also be added to forestall the unfold of Legionnaire illness.